ERHQ006BAV3 ERHQ007BAV3 ERHQ008BAV3 ERHQ011BAV3 ERHQ014BAV3 ERHQ016BAV3
Casing Colour   Ivory white Ivory white Ivory white Ivory white Ivory white Ivory white
  Material   Polyester painted steel sheet plate Polyester painted steel sheet plate Polyester painted steel sheet plate Painted galvanized steel plate Painted galvanized steel plate Painted galvanized steel plate
Dimensions Unit Height mm 735 735 735 1,170 1,170 1,170
    Width mm 825 825 825 900 900 900
    Depth mm 300 300 300 320 320 320
  Packed unit Height mm 797 797 797 1,349 1,349 1,349
    Width mm 960 960 960 980 980 980
    Depth mm 390 390 390 420 420 420
Weight Unit kg 56 56 56 102 102 102
  Packed unit kg 61 61 61 118 118 118
Packing Material   EPS, Carton EPS, Carton EPS, Carton Wood, EPS, Carton, PE (Straps) Wood, EPS, Carton, PE (Straps) Wood, EPS, Carton, PE (Straps)
  Weight kg 5 5 5 11 11 11
Heat exchanger Length mm 845 845 845 857 857 857
  Rows Quantity   2 2 2 2 2 2
  Fin pitch mm 1.8 1.8 1.8 1.40 1.40 1.40
  Passes Quantity       6 6 6
  Face area       0.980 0.980 0.980
  Stages Quantity   32 32 32 52 52 52
  Empty tubeplate hole Quantity       0 0 0
  Tube type   ø8 Hi-XA ø8 Hi-XA ø8 Hi-XA ø8 Hi-XSS ø8 Hi-XSS ø8 Hi-XSS
  Fin Type   WF fin WF fin WF fin WF fin WF fin WF fin
    Treatment   Anti-corrosion treatment (PE) Anti-corrosion treatment (PE) Anti-corrosion treatment (PE) Anti-corrosion treatment (PE) Anti-corrosion treatment (PE) Anti-corrosion treatment (PE)
Fan Type   Propeller fan Propeller fan Propeller fan Propeller fan Propeller fan Propeller fan
  Quantity   1 1 1 2 2 2
  Air flow rate Heating Nom. m³/min       90.0 90.0 90.0
    Cooling Nom. m³/min       96.0 100.0 97.0
  Discharge direction   Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal
Fan motor Quantity   1 1 1 2 2 2
  Model       Brushless DC motor Brushless DC motor Brushless DC motor
  Output W 53.00 53.00 53.00 70.00 70.00 70.00
  Drive       Direct drive Direct drive Direct drive
  Speed Steps       8 8 8
    Heating Nom. rpm       760 760 760
    Cooling Nom. rpm       800 850 830
Compressor Quantity   1 1 1 1 1 1
  Model   2YC63BXD#C 2YC63BXD#C 2YC63BXD#C JT100G-VD JT100G-VD JT100G-VD
  Type   Hermetically sealed swing compressor Hermetically sealed swing compressor Hermetically sealed swing compressor Hermetically sealed scroll compressor Hermetically sealed scroll compressor Hermetically sealed scroll compressor
  Output W 1,920 1,920 1,920 2,200.0 2,200.0 2,200.0
  Starting method       Inverter driven Inverter driven Inverter driven
  Motor Crankcase heater Quantity       1 1 1
      Output W       33 33 33
PED Category       Category I, Excluded from scope of PED due to article 1, item 3.6 of 97/23/EC Category I, Excluded from scope of PED due to article 1, item 3.6 of 97/23/EC Category I, Excluded from scope of PED due to article 1, item 3.6 of 97/23/EC
Operation range Heating Min. °CWB -20 -20 -20      
    Min. °CDB       -20 (1) -20 (1) -20 (1)
    Max. °CWB 25 25 25      
    Max. °CDB       35 35 35
  Cooling Min. °CDB 10 10 10 10.0 10.0 10.0
    Max. °CDB 43 43 43 46.0 46.0 46.0
  Domestic hot water Min. °CDB -20 -20 -20 -20 (2) -20 (2) -20 (2)
    Max. °CDB 43 43 43 35 (2) 35 (2) 35 (2)
Sound power level Heating Nom. dBA 61 61 62 64 (3) 64 (3) 66 (3)
  Cooling Nom. dBA 63 63 63 64 (4) 66 (4) 69 (4)
Sound pressure level Heating Nom. dBA 48 48 49 49 (5) 51 (5) 53 (5)
  Cooling Nom. dBA 48 48 50 50 (6) 52 (6) 54 (6)
  Night quiet mode Heating dBA       42 (7) 42 (7) 43 (7)
    Cooling dBA       45 (7) 45 (7) 46 (7)
Refrigerant Type   R-410A R-410A R-410A R-410A R-410A R-410A
  GWP   2,087.5 2,087.5 2,087.5 2,087.5 2,087.5 2,087.5
  Charge TCO2Eq 3.5 3.5 3.5 5.6 5.6 5.6
  Charge kg 1.7 1.7 1.7 2.7 2.7 2.7
  Control   Expansion valve (electronic type) Expansion valve (electronic type) Expansion valve (electronic type) Expansion valve (electronic type) Expansion valve (electronic type) Expansion valve (electronic type)
  Circuits Quantity   1 1 1 1 1 1
Refrigerant oil Type   FVC50K FVC50K FVC50K Daphne FVC68D Daphne FVC68D Daphne FVC68D
  Charged volume l 0.75 0.75 0.75 1.5 1.5 1.5
Piping connections Liquid Quantity       1 1 1
    Type   Flare connection Flare connection Flare connection Flare connection Flare connection Flare connection
    OD mm 6.35 6.35 6.35 9,52 9,52 9,52
  Gas Quantity       1 1 1
    Type   Flare connection Flare connection Flare connection Flare connection Flare connection Flare connection
    OD mm 15.9 15.9 15.9 15.90 15.90 15.90
  Drain Quantity   1 1 1 3 3 3
    Type   Socket Socket Socket Hole Hole Hole
    OD mm 18 18 18 26 26 26
  Piping length OU - IU Min. m 3 3 3 3 3 3
      Max. m 30 30 30 75 75 75
    System Equivalent m       95 (0.000) 95 (0.000) 95 (0.000)
      Chargeless m       10 10 10
  Additional refrigerant charge kg/m 0.02 (for piping length exceeding 10m) 0.02 (for piping length exceeding 10m) 0.02 (for piping length exceeding 10m) See installation manual See installation manual See installation manual
  Level difference IU - OU Max. m       30.0 30.0 30.0
    IU - IU Max. m 20 20 20      
  Heat insulation       Both liquid and gas pipes Both liquid and gas pipes Both liquid and gas pipes
Defrost method Reversed cycle Reversed cycle Reversed cycle Reversed cycle Reversed cycle Reversed cycle
Defrost control Sensor for outdoor heat exchanger temperature Sensor for outdoor heat exchanger temperature Sensor for outdoor heat exchanger temperature Sensor for outdoor heat exchanger temperature Sensor for outdoor heat exchanger temperature Sensor for outdoor heat exchanger temperature
Capacity control Method   Inverter controlled Inverter controlled Inverter controlled Inverter controlled Inverter controlled Inverter controlled
Standard Accessories Installation manual 1 1 1      
  Drain plug 1 1 1      
Power supply Name   V3 V3 V3 V3 V3 V3
  Phase   1~ 1~ 1~ 1~ 1~ 1~
  Frequency Hz 50 50 50 50 50 50
  Voltage V 230 230 230 230 230 230
  Voltage range Min. % -10 -10 -10 -10 -10 -10
    Max. % 10 10 10 10 10 10
Current Minimum Ssc value kVa       Equipment complying with EN / IEC 61000-3-12 Equipment complying with EN / IEC 61000-3-12 Equipment complying with EN / IEC 61000-3-12
  Starting current Heating A 11 11 11      
    Cooling A 11 11 11      
  Maximum running current Heating A 18 18 18      
    Cooling A 16.25 16.25 16.25 23 27 32
  Recommended fuses A 20 20 20 32 32 32
Wiring connections For power supply Quantity   3 3 3      
    Remark       See installation manual indoor unit See installation manual indoor unit See installation manual indoor unit
  For connection with indoor Quantity   4 4 4      
    Remark   Earth wire included Earth wire included Earth wire included See installation manual indoor unit See installation manual indoor unit See installation manual indoor unit
Notes See separate drawing for operation range See separate drawing for operation range See separate drawing for operation range Operation range heating (outdoor unit): range increase by support back-up heater. See separate drawing for operation range. Operation range heating (outdoor unit): range increase by support back-up heater. See separate drawing for operation range. Operation range heating (outdoor unit): range increase by support back-up heater. See separate drawing for operation range.
  The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information. The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information. The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information. Operation range domestic hot water (outdoor unit): range increase by support booster heater or backup heater. See separate drawing for operation range. Operation range domestic hot water (outdoor unit): range increase by support booster heater or backup heater. See separate drawing for operation range. Operation range domestic hot water (outdoor unit): range increase by support booster heater or backup heater. See separate drawing for operation range.
  Minimum Ssc value: Equipment complying with EN/IEC 61000-3-12: European/International Technical Standard setting the limits for harmonic currents produced by equipment connected to public low-voltage systems with input current >16A and ≤ 75A per phase Minimum Ssc value: Equipment complying with EN/IEC 61000-3-12: European/International Technical Standard setting the limits for harmonic currents produced by equipment connected to public low-voltage systems with input current >16A and ≤ 75A per phase Minimum Ssc value: Equipment complying with EN/IEC 61000-3-12: European/International Technical Standard setting the limits for harmonic currents produced by equipment connected to public low-voltage systems with input current >16A and ≤ 75A per phase Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
  Contains fluorinated greenhouse gases Contains fluorinated greenhouse gases Contains fluorinated greenhouse gases Condition: Ta 35°C - LWE 7°C ( DT = 5°C) Condition: Ta 35°C - LWE 7°C ( DT = 5°C) Condition: Ta 35°C - LWE 7°C ( DT = 5°C)
        The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information. Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C). The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information. Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C). The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information. Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C).
        The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information. Condition: Ta 35°C - LWE 7°C ( DT = 5°C). The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information. Condition: Ta 35°C - LWE 7°C ( DT = 5°C). The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information. Condition: Ta 35°C - LWE 7°C ( DT = 5°C).
        The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information. The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information. The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information.
        Contains fluorinated greenhouse gases Contains fluorinated greenhouse gases Contains fluorinated greenhouse gases