ERSQ011AAV1 ERSQ014AAV1 ERSQ016AAV1
Casing Colour   Daikin White Daikin White Daikin White
  Material   Painted galvanized steel plate Painted galvanized steel plate Painted galvanized steel plate
Dimensions Unit Height mm 1,345 1,345 1,345
    Width mm 900 900 900
    Depth mm 320 320 320
  Packed unit Height mm 1,524 1,524 1,524
    Width mm 980 980 980
    Depth mm 420 420 420
Weight Unit kg 120 120 120
  Packed unit kg 130 130 130
Packing Material   Wood, EPS, Cardboard Wood, EPS, Cardboard Wood, EPS, Cardboard
  Weight kg 8 8 8
Heat exchanger Length mm 857 857 857
  Rows Quantity   2 2 2
  Fin pitch mm 2 2 2
  Passes Quantity   10 10 10
  Face area 1.131 1.131 1.131
  Stages Quantity   60 60 60
  Empty tubeplate hole Quantity   0 0 0
  Tube type   Hi-XSS Hi-XSS Hi-XSS
  Fin Type   Non-symmetric waffle louvre Non-symmetric waffle louvre Non-symmetric waffle louvre
    Treatment   Corrosion resistant Corrosion resistant Corrosion resistant
Fan Type   Propeller fan Propeller fan Propeller fan
  Quantity   2 2 2
  Discharge direction   Horizontal Horizontal Horizontal
Fan motor Quantity   2 2 2
  Model   Brushless DC motor Brushless DC motor Brushless DC motor
  Output W 70 70 70
  Drive   Direct drive Direct drive Direct drive
Compressor Quantity   1 1 1
  Type   Hermetically sealed scroll compressor Hermetically sealed scroll compressor Hermetically sealed scroll compressor
  Starting method   Direct on line Direct on line Direct on line
  Motor Crankcase heater Quantity   1 1 1
      Output W 33 33 33
Operation range Heating Min. °CWB -20 -20 -20
    Max. °CWB 20 20 20
  Domestic hot water Min. °CDB -20 -20 -20
    Max. °CDB 35 35 35
Piping connections Liquid Quantity   1 1 1
    Type   Flare connection Flare connection Flare connection
    OD mm 9.52 9.52 9.52
  Gas Quantity   1 1 1
    Type   Flare connection Flare connection Flare connection
    OD mm 15.9 15.9 15.9
  Drain Quantity   3 3 3
    OD mm 26x3 26x3 26x3
  Piping length OU - IU Min. m 3 3 3
      Max. m 50 50 50
    System Equivalent m 63 63 63
      Chargeless m 10 10 10
  High pressure side Design pressure bar 40 40 40
  Additional refrigerant charge kg/m See installation manual See installation manual See installation manual
  Level difference IU - OU Max. m 30 30 30
  Heat insulation   Both liquid and gas pipes Both liquid and gas pipes Both liquid and gas pipes
Sound power level Heating Nom. dBA 68 69 71
Sound pressure level Heating Nom. dBA 52 53 55
Refrigerant Type   R-410A R-410A R-410A
  GWP   2,087.5 2,087.5 2,087.5
  Charge TCO2Eq 9.4 9.4 9.4
  Charge kg 4.5 4.5 4.5
  Control   Expansion valve (electronic type) Expansion valve (electronic type) Expansion valve (electronic type)
  Circuits Quantity   1 1 1
Refrigerant oil Type   Daphne FVC68D Daphne FVC68D Daphne FVC68D
  Charged volume l 1.5 1.5 1.5
Defrost method Reversed cycle Reversed cycle Reversed cycle
Defrost control Sensor for outdoor heat exchanger temperature Sensor for outdoor heat exchanger temperature Sensor for outdoor heat exchanger temperature
Capacity control Method   Inverter controlled Inverter controlled Inverter controlled
Safety devices Item 01   High pressure switch High pressure switch High pressure switch
    02   Fan motor thermal protection Fan motor thermal protection Fan motor thermal protection
    03   Inverter overload protector Inverter overload protector Inverter overload protector
    04   PC board fuse PC board fuse PC board fuse
Quantity Installation manual Installation manual Installation manual
Power supply Name   V1 V1 V1
  Phase   1~ 1~ 1~
  Frequency Hz 50 50 50
  Voltage V 220-440 220-440 220-440
  Voltage range Min. % -10 -10 -10
    Max. % 10 10 10
Current Zmax Text Ω 0.28 0.28 0.28
  Maximum running current Heating A 23.8 23.8 23.8
  Recommended fuses A 25 25 25
Wiring connections For power supply Quantity   2G 2G 2G
    Remark   Select diameter and type according to national and local regulations Select diameter and type according to national and local regulations Select diameter and type according to national and local regulations
  For connection with indoor Quantity   2 2 2
    Remark   F1,F2 F1,F2 F1,F2
Power supply intake Both indoor and outdoor unit Both indoor and outdoor unit Both indoor and outdoor unit
Notes (1) - See separate drawing for operation range (1) - See separate drawing for operation range (1) - See separate drawing for operation range
  (2) - Zmax: In accordance with EN/IEC 61000-3-11, it may be necessary to consult the distribution network operator to ensure that the equipment is connected only to a supply with Zsys (system impedance) ≤ Zmax (2) - Zmax: In accordance with EN/IEC 61000-3-11, it may be necessary to consult the distribution network operator to ensure that the equipment is connected only to a supply with Zsys (system impedance) ≤ Zmax (2) - Zmax: In accordance with EN/IEC 61000-3-11, it may be necessary to consult the distribution network operator to ensure that the equipment is connected only to a supply with Zsys (system impedance) ≤ Zmax
  (3) - EN/IEC 61000-3-11: European/international technical standard setting the limits for voltage changes, voltage fluctuations and flicker in public low-voltage supply systems for equipment with rated ≤ 75A (3) - EN/IEC 61000-3-11: European/international technical standard setting the limits for voltage changes, voltage fluctuations and flicker in public low-voltage supply systems for equipment with rated ≤ 75A (3) - EN/IEC 61000-3-11: European/international technical standard setting the limits for voltage changes, voltage fluctuations and flicker in public low-voltage supply systems for equipment with rated ≤ 75A
  (4) - Minimum Ssc (=Short-circuit power) value: Equipment complying with EN/IEC 61000-3-12: European/International Technical Standard setting the limits for harmonic currents produced by equipment connected to public low-voltage systems with input current >16A and ≤ 75A per phase (4) - Minimum Ssc (=Short-circuit power) value: Equipment complying with EN/IEC 61000-3-12: European/International Technical Standard setting the limits for harmonic currents produced by equipment connected to public low-voltage systems with input current >16A and ≤ 75A per phase (4) - Minimum Ssc (=Short-circuit power) value: Equipment complying with EN/IEC 61000-3-12: European/International Technical Standard setting the limits for harmonic currents produced by equipment connected to public low-voltage systems with input current >16A and ≤ 75A per phase
  (5) - Contains fluorinated greenhouse gases (5) - Contains fluorinated greenhouse gases (5) - Contains fluorinated greenhouse gases