Specifications Table for RKXYQ-T

RKXYQ5TY1B RKXYQ8TY1B RKXYQ5T7Y1B RKXYQ8T7Y1B
Sound pressure level Cooling Nom. dBA 47 (5) 48 (5) 47.0 (5)  
Refrigerant Charge TCO2Eq 4.20 8.35 4.20  
  Charge kg 2.00 4.00 2.00  
  Refrigerant-=-Refrigerant type 2,087.5 2,087.5    
Packing 3 Weight kg 0.3 0.3    
  Material Plastic Plastic    
Packing Weight kg 2.1 2.2    
  Material Carton Carton    
Packing 2 Weight kg 6.9 8.5    
  Material Wood Wood    
Sound power level Cooling Nom. dBA 60 (4) 64 (4)    
Dimensions Packed unit Width mm 720 875    
    Height mm 838 825    
    Depth mm 660 660    
  Unit Width mm 600 760 600 760
    Depth mm 554 554 554 554
    Height mm 701 701 701 701
Compressor Crankcase heater W   33    
  Compressor-=-Compressor quantity Hermetically sealed swing inverter compressor G-type scroll compressor    
Casing Colour Painted galvanized steel plate Painted galvanized steel plate    
PED Most critical part Ps*V Bar*l 167 245    
  Category Category I Category II    
Weight Packed unit kg 86 116    
  Unit kg 77 105 77 105
Refrigerant oil Type Synthetic (ether) oil Daphne FVC68D    
Current - 50Hz Minimum circuit amps (MCA) A 13.5 17.4    
  Total overcurrent amps (TOCA) A 13.5 17.4    
  Maximum fuse amps (MFA) A 16 20   20 (11)
Voltage range Min. % -10 -10    
  Max. % 10 10    
Power supply Frequency Hz 50 50 50 50
  Voltage V 380-415 380-415 380-415 380-415
  Phase 3N~ 3N~    
Wiring connections - 50Hz For power supply Quantity 5G 5G    
Current Nominal running current (RLA) - 50Hz Cooling A 5.8 8.6    
Notes Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. Data for standard efficiency series. Nominal air flow rate, ESP 30 Pa. Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. Data for standard efficiency series. Nominal air flow rate, ESP 30 Pa. (1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m; level difference: 0m (1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m; level difference: 0m
  Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. Data for standard efficiency series. Nominal air flow rate, ESP 30 Pa. Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. Data for standard efficiency series. Nominal air flow rate, ESP 30 Pa. (2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m; level difference: 0m (2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m; level difference: 0m
  Actual number of units depends on the indoor unit type (VRV DX indoor, etc.) and the connection ratio restriction for the system (being; 50% ≤ CR ≤ 130%). Actual number of units depends on the indoor unit type (VRV DX indoor, etc.) and the connection ratio restriction for the system (being; 50% ≤ CR ≤ 130%). (3) - Actual number of units depends on the indoor unit type (VRV DX indoor, etc.) and the connection ratio restriction for the system (being; 50% ≤ CR ≤ 130%). (3) - Actual number of units depends on the indoor unit type (VRV DX indoor, etc.) and the connection ratio restriction for the system (being; 50% ≤ CR ≤ 130%).
  The sound power level is an absolute value indicating the power which a sound source generates. The sound power level is an absolute value indicating the power which a sound source generates. (4) - Sound power level is an absolute value that a sound source generates. (4) - Sound power level is an absolute value that a sound source generates.
  Sound pressure level is a relative value, depending on the distance and acoustic environment. For more details, please refer to sound level drawings. Nominal air flow rate, ESP 60 Pa. Sound pressure level is a relative value, depending on the distance and acoustic environment. For more details, please refer to sound level drawings. Nominal air flow rate, ESP 60 Pa. (5) - Sound pressure level is a relative value, depending on the distance and acoustic environment. For more details, please refer to the sound level drawings. (5) - Sound pressure level is a relative value, depending on the distance and acoustic environment. For more details, please refer to the sound level drawings.
  Refer to refrigerant pipe selection or installation manual Refer to refrigerant pipe selection or installation manual (6) - Refer to refrigerant pipe selection or installation manual (6) - Refer to refrigerant pipe selection or installation manual
  In accordance with EN/IEC 61000-3-12, it may be necessary to consult the distribution network operator to ensure that the equipment is connected only to a supply wih Ssc ≥ minimum Ssc value In accordance with EN/IEC 61000-3-12, it may be necessary to consult the distribution network operator to ensure that the equipment is connected only to a supply wih Ssc ≥ minimum Ssc value (7) - RLA is based on following conditions: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB (7) - RLA is based on following conditions: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB
  Sound values are measured in a semi-anechoic room. Sound values are measured in a semi-anechoic room. (8) - MSC means the maximum current during start up of the compressor. This unit uses only inverter compressors. Starting current is always ≤ max. running current. (8) - MSC means the maximum current during start up of the compressor. This unit uses only inverter compressors. Starting current is always ≤ max. running current.
  Contains fluorinated greenhouse gases Contains fluorinated greenhouse gases (9) - In accordance with EN/IEC 61000-3-12, it may be necessary to consult the distribution network operator to ensure that the equipment is connected only to a supply wih Ssc ≥ minimum Ssc value (9) - In accordance with EN/IEC 61000-3-12, it may be necessary to consult the distribution network operator to ensure that the equipment is connected only to a supply wih Ssc ≥ minimum Ssc value
Wiring connections - 50Hz For connection with indoor Quantity   F1,F2    
Compressor Type       Hermetically sealed swing compressor  
Sound power level Cooling Nom. dBA     60.0 (4)  
Refrigerant Type       R-410A R-410A
  GWP       2,087.5  
Standard Accessories Installation and operation manual     1 1
  Connection pipes     4 5
  Declaration of conformity     1 1
  Refrigerant label for F-gas regulation     1 1
  Tie-wraps     3 3
  Screws     1 1
Power supply Name       Y1 Y1
  Phase       3N~ 3N~
Notes     (10) - MCA must be used to select the correct field wiring size. The MCA can be regarded as the maximum running current. (10) - MCA must be used to select the correct field wiring size. The MCA can be regarded as the maximum running current.
      (11) - MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker). (11) - MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker).
      (12) - TOCA means the total value of each OC set. (12) - TOCA means the total value of each OC set.
      (13) - FLA means the nominal running current of the fan (13) - FLA means the nominal running current of the fan
      (14) - Maximum allowable voltage range variation between phases is 2%. (14) - Maximum allowable voltage range variation between phases is 2%.
      (15) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits. (15) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits.
      (16) - Sound values are measured in a semi-anechoic room. (16) - Sound values are measured in a semi-anechoic room.
      (17) - EN/IEC 61000-3-12: European/international technical standard setting the limits for harmonic currents produced by equipment connected to public low-voltage system with input current > 16A and ≤ 75A per phase (17) - EN/IEC 61000-3-12: European/international technical standard setting the limits for harmonic currents produced by equipment connected to public low-voltage system with input current > 16A and ≤ 75A per phase
      (18) - Ssc: Short-circuit power (18) - Ssc: Short-circuit power
      (19) - For detailed contents of standard accessories, see installation/operation manual (19) - For detailed contents of standard accessories, see installation/operation manual
Casing Colour         Daikin White
  Material         Painted galvanized steel plate
Refrigerant GWP         2,087.5