| ADEA35A2VEB / ARXM35A5V1B9 | ADEA50A2VEB / ARXM50A5V1B9 | ||||
|---|---|---|---|---|---|
| Cooling capacity | Nom. | kW | 3.4 | 5 | |
| Heating capacity | Nom. | kW | 4 | 5.5 | |
| Nominal efficiency | EER | 3.76 | 3.27 | ||
| COP | 3.97 | 3.74 | |||
| Annual energy consumption | kWh | 452 | 765 | ||
| Energy labeling Directive | Cooling | A | A | ||
| Heating | A | A | |||
| Space cooling | Energy efficiency class | A+ | A+ | ||
| Capacity | Pdesign | kW | 3.4 | 5 | |
| SEER | 5.9 | 5.65 | |||
| Annual energy consumption | kWh/a | 202 | 310 | ||
| Space heating (Average climate) | Energy efficiency class | A+ | A+ | ||
| Capacity | Pdesign | kW | 2.9 | 4.4 | |
| SCOP/A | 4.07 | 4 | |||
| Pdh Heating capacity at -10° | kW | 2.32 | 3.73 | ||
| Annual energy consumption | kWh/a | 997 | 1538 | ||
| Notes | (1) - See separate drawing for operation range | (1) - See separate drawing for operation range | |||
| (2) - See separate drawing for electrical data | (2) - See separate drawing for electrical data | ||||
| (3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | (3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | ||||
| (4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | (4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | ||||