Specifications Table for CTXM-R / 2MXM-A9

CTXM15R5V1B / CTXM15R5V1B / 2MXM40A2V1B9 CTXM15R2V1B / CTXM15R2V1B / 2MXM40A2V1B9 CTXM15R2V1B / CTXM15R2V1B / 2MXM50A2V1B9 CTXM15R5V1B / CTXM15R5V1B / 2MXM50A2V1B9
Cooling capacity Nom. kW 3.00 3.00 3.00 3.00
Heating capacity Nom. kW 3.50 3.50 4.00 4.00
Nominal efficiency Annual energy consumption kWh 302 302 310 310
  COP   4.35 4.35 4.58 4.58
  EER   4.97 4.97 4.84 4.84
  Energy labeling Directive Cooling   A A A A
    Heating   A A A A
Space cooling Annual energy consumption kWh/a 122 122 119 119
  Energy efficiency class   A+++ A+++ A+++ A+++
  Capacity Pdesign kW 3.00 3.00 3.00 3.00
  SEER   8.66 8.66 8.81 8.81
Space heating (Average climate) Annual energy consumption kWh/a 908 908 971 971
  Capacity Pdesign kW 3.00 3.00 3.30 3.30
  Energy efficiency class   A++ A++ A++ A++
  Pdh Heating capacity at -10° kW 2.41 2.41 2.65 2.65
  SCOP/A   4.62 4.62 4.76 4.76
Notes (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
  (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
  (3) - See separate drawing for operation range (3) - See separate drawing for operation range (3) - See separate drawing for operation range (3) - See separate drawing for operation range
  (4) - See separate drawing for electrical data (4) - See separate drawing for electrical data (4) - See separate drawing for electrical data (4) - See separate drawing for electrical data