Specifications Table for EDLA-D3V37

EDLA16DA3V37
Heating capacity Nom. kW 16.0 (2) (1)
Heater capacity Step 1 kW 3
Power input Heating Nom. kW 3.53 (1), 4.56 (2)
COP 4.53 (1), 3.51 (2)
Dimensions Unit Height mm 870
    Width mm 1380
    Depth mm 460
Weight Unit kg 149
Fan Air flow rate Heating High m³/min 85.0
Operation range Heating Water side Min. °C 15 (6)
      Max. °C 60 (6)
  Domestic hot water Ambient Min. °CDB -25
      Max. °CDB 35
    Water side Min. °C 25
      Max. °C 55 (6)
Refrigerant Type   R-32
  GWP   675
  Charge kg 3.80
  Charge tCO2Eq 2.57
Space heating Average climate water outlet 55°C General SCOP   3.33
      Seasonal space heating eff. class   A++
  Average climate water outlet 35°C General SCOP   4.62
      Seasonal space heating eff. class   A+++
Compressor component Main power supply Phase   1~
    Voltage V 230
Power supply Name   V3
  Phase   1~
  Frequency Hz 50
  Voltage V 230
Notes (1) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
  (2) - Condition: Ta DB/WB 7°C/6°C - LWC 45°C (Dt=5°C)
  (3) - For more details, see operation range drawing
  (4) - Depends on operation mode, refer to installation manual.