| EHVX04S23EJ3V / ERGA04EAV37 | EHVX04S18EA3V / ERGA04EAV37 | EHVX04S18EJ3V / ERGA04EAV37 | EHVX04S23EA3V / ERGA04EAV37 | |||||
|---|---|---|---|---|---|---|---|---|
| Heating capacity | Nom. | kW | 4.36, 4.60 | 4.36, 4.60 | 4.36, 4.60 | 4.36, 4.60 | ||
| Cooling capacity | Nom. | kW | 4.86, 4.52 | 4.86, 4.52 | 4.86, 4.52 | 4.86, 4.52 | ||
| Power input | Heating | Nom. | kW | 0.830, 1.26 | 0.830, 1.26 | 0.830, 1.26 | 0.830, 1.26 | |
| Cooling | Nom. | kW | 0.810, 1.36 | 0.810, 1.36 | 0.810, 1.36 | 0.810, 1.36 | ||
| Domestic hot water from 10°C to 50°C | Nom. | kWh | 3.01 | 2.48 | 2.48 | 3.01 | ||
| Heat up time from 10°C to 50°C | hr | 1h40min | 1h28min | 1h28min | 1h40min | |||
| COP | 5.23, 3.65 | 5.23, 3.65 | 5.23, 3.65 | 5.23, 3.65 | ||||
| EER | 5.98, 3.32 | 5.98, 3.32 | 5.98, 3.32 | 5.98, 3.32 | ||||
| Domestic hot water heating | General | Declared load profile | XL | L | L | XL | ||
| Average climate | Water heating energy efficiency class | A | A | A | A | |||
| Space heating | Average climate water outlet 55°C | General | SCOP | 3.29 | 3.29 | 3.29 | 3.29 | |
| Seasonal space heating eff. class | A++ | A++ | A++ | A++ | ||||
| Average climate water outlet 35°C | General | SCOP | 4.96 | 4.96 | 4.96 | 4.96 | ||
| Seasonal space heating eff. class | A+++ | A+++ | A+++ | A+++ | ||||
| Notes | (1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | (1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | (1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | (1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | ||||
| (2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) | (2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) | (2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) | (2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) | |||||