| EPGA11DAV3 | EPGA14DAV3 | EPGA16DAV3 | |||||
|---|---|---|---|---|---|---|---|
| Sound pressure level | Heating | Nom. | dBA | 48.0 (2) | 49.0 (2) | 52.0 (2) | |
| Cooling | Nom. | dBA | 55.0 (3) | 55.0 (3) | 55.0 (3) | ||
| Sound power level | Heating | Nom. | dBA | 64.0 (1) | 64.0 (1) | 66.0 (1) | |
| Cooling | Nom. | dBA | 68.0 (1) | 68.0 (1) | 68.0 (1) | ||
| Refrigerant | GWP | 675.0 | 675.0 | 675.0 | |||
| Charge | kg | 3.50 | 3.50 | 3.50 | |||
| Type | R-32 | R-32 | R-32 | ||||
| Dimensions | Unit | Width | mm | 1,160 | 1,160 | 1,160 | |
| Depth | mm | 380 | 380 | 380 | |||
| Height | mm | 1,440 | 1,440 | 1,440 | |||
| Weight | Unit | kg | 143 | 143 | 143 | ||
| Operation range | Cooling | Max. | °CDB | 43 | 43 | 43 | |
| Min. | °CDB | 10 | 10 | 10 | |||
| Domestic hot water | Min. | °CDB | -28 | -28 | -28 | ||
| Max. | °CDB | 35 | 35 | 35 | |||
| Piping connections | Level difference | IU - OU | Max. | m | 10.0 | 10.0 | 10.0 |
| Power supply | Phase | 1N~ | 1N~ | 1N~ | |||
| Name | V3 | V3 | V3 | ||||
| Frequency | Hz | 50 | 50 | 50 | |||
| Voltage | V | 230 | 230 | 230 | |||
| Current | Recommended fuses | A | 32 | 32 | 32 | ||
| Notes | (1) - Cooling Ta 35°C - LWE 18°C (DT = 5°C); Heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | (1) - Cooling Ta 35°C - LWE 18°C (DT = 5°C); Heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | (1) - Cooling Ta 35°C - LWE 18°C (DT = 5°C); Heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | ||||
| (2) - The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information. Condition: Ta DB/WB 7°C/6°C - LWC 3 | (2) - The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information. Condition: Ta DB/WB 7°C/6°C - LWC 3 | (2) - The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information. Condition: Ta DB/WB 7°C/6°C - LWC 3 | |||||
| (3) - The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information. Condition: Ta 35°C - LWE 7°C ( DT = | (3) - The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information. Condition: Ta 35°C - LWE 7°C ( DT = | (3) - The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information. Condition: Ta 35°C - LWE 7°C ( DT = | |||||