Specifications Table for FBA-A / RZQSG-L3/9V1

FBA35A2VEB / FBA35A2VEB / RZQSG71L3V1B FBA35A2VEB / FBA35A2VEB / FBA35A2VEB / RZQSG100L9V1B FBA50A2VEB / FBA50A2VEB / RZQSG100L9V1B FBA35A2VEB / FBA35A2VEB / FBA35A2VEB / FBA35A2VEB / RZQSG125L9V1B FBA50A2VEB / FBA50A2VEB / FBA50A2VEB / RZQSG125L9V1B FBA60A2VEB / FBA60A2VEB / RZQSG125L9V1B FBA35A2VEB / FBA35A2VEB / FBA35A2VEB / FBA35A2VEB / RZQSG140L9V1B FBA71A2VEB / RZQSG71L3V1B
Space cooling SEER   5.10 5.10 5.10 4.80 4.80 4.80   5.84
  Annual energy consumption kWh/a 467 652 652 875 875 875   408
  Capacity Pdesign kW 6.80 9.50 9.50 12.0 12.0 12.0   6.80
  Energy efficiency class   A A A B B B   A+
Space heating (Average climate) Capacity Pdesign kW 6.00 7.60 7.60 7.60 7.60 7.60   6.00
  SCOP/A   3.80 3.80 3.80 3.80 3.80 3.80   4.01
  Energy efficiency class   A A A A A A   A+
  Annual energy consumption kWh/a 2,211 2,800 2,800 2,800 2,800 2,800   2,095
Notes (1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m; level difference: 0m (1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m; level difference: 0m (1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m; level difference: 0m (1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m; level difference: 0m (1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m; level difference: 0m (1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m; level difference: 0m (1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m; level difference: 0m (1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m; level difference: 0m
  (2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m; level difference: 0m (2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m; level difference: 0m (2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m; level difference: 0m (2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m; level difference: 0m (2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m; level difference: 0m (2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m; level difference: 0m (2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m; level difference: 0m (2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m; level difference: 0m
  (3) - EER/COP according to Eurovent 2012, for use outside EU only (3) - EER/COP according to Eurovent 2012, for use outside EU only (3) - EER/COP according to Eurovent 2012, for use outside EU only (3) - EER/COP according to Eurovent 2012, for use outside EU only (3) - EER/COP according to Eurovent 2012, for use outside EU only (3) - EER/COP according to Eurovent 2012, for use outside EU only (3) - EER/COP according to Eurovent 2012, for use outside EU only (3) - EER/COP according to Eurovent 2012, for use outside EU only
Cooling capacity Nom. kW     9.50 (1) 12.0 (1) 12.0 (1) 12.0 (1) 13.4 (1) 6.80 (1)
Nominal efficiency EER       3.06 (3) 3.04 (3) 2.94 (3) 2.83 (3) 4.20 (3) 3.43 (3)
  COP       3.30 (3) 3.35 (3) 3.30 (3) 3.26 (3)   3.92 (3)
  Energy labeling Directive Cooling       B B C C   A
    Heating       C C C C   A
Heating capacity Nom. kW     10.8 (2) 13.5 (2) 13.5 (2) 13.5 (2) 15.5 (2) 7.50 (2)
Nominal efficiency Annual energy consumption kWh               991