Specifications Table for FCQG-F / RZQSG-LV1/LY1

FCQG35FVEB / FCQG35FVEB / RZQSG71L2V1B FCQG71FVEB / RZQSG71L2V1B FCQG100FVEB / RZQSG100L7V1B FCQG100FVEB / RZQSG100L7Y1B9 FCQG100FVEB / RZQSG100L7Y1B FCQG35FVEB / FCQG35FVEB / FCQG35FVEB / RZQSG100L7V1B FCQG35FVEB / FCQG35FVEB / FCQG35FVEB / RZQSG100L7Y1B9 FCQG50FVEB / FCQG50FVEB / RZQSG100L7V1B FCQG50FVEB / FCQG50FVEB / RZQSG100L7Y1B9 FCQG125FVEB / RZQSG125L7V1B FCQG125FVEB / RZQSG125L7Y1B9 FCQG125FVEB / RZQSG125L7Y1B FCQG35FVEB / FCQG35FVEB / FCQG35FVEB / FCQG35FVEB / RZQSG125L7V1B FCQG35FVEB / FCQG35FVEB / FCQG35FVEB / FCQG35FVEB / RZQSG125L7Y1B9 FCQG50FVEB / FCQG50FVEB / FCQG50FVEB / RZQSG125L7V1B FCQG50FVEB / FCQG50FVEB / FCQG50FVEB / RZQSG125L7Y1B9 FCQG60FVEB / FCQG60FVEB / RZQSG125L7V1B FCQG60FVEB / FCQG60FVEB / RZQSG125L7Y1B9
Cooling capacity Nom. kW   6.8 9.5 9.5 9.5 (3)         12.0 12.0 12.0 (3)
Space cooling SEER   4.30 5.11 5.11 5.11 5.11 (6) 4.30 4.30 4.30 4.30 5.11 5.11 5.11 (6) 4.00 4.00 4.30 4.30 4.30 4.30
  Annual energy consumption kWh/a 554 466 650.685 650.685   773.256 773.256 773.256 773.256 821.918 821.918   1,050 1,050 976.744 976.744 976.744 976.744
  Capacity Pdesign kW 6.80 6.80 9.50 9.50   9.50 9.50 9.50 9.50 12.00 12.00   12.00 12.00 12.00 12.00 12.00 12.00
  Energy efficiency class   C A A A   C C C C A A   D D C C C C
Space heating (Average climate) Capacity Pdesign kW 6.00 6.33 7.60 7.60   6.81 6.81 6.81 6.81 8.03 8.03   8.03 8.03 8.03 8.03 8.03 8.03
  SCOP/A   3.40 3.81 3.80 3.80 3.80 (6) 3.40 3.40 3.40 3.40 3.81 3.81 3.81 (6) 3.40 3.40 3.40 3.40 3.40 3.40
  Energy efficiency class   A A A A   A A A A A A   A A A A A A
  Annual energy consumption kWh/a 2,472 2,327 2,799 2,799   2,802 2,802 2,802 2,802 2,949 2,949   3,305 3,305 3,305 3,305 3,306.471 3,306.471
Nominal efficiency EER     3.21 3.30 3.30 3.30         3.21 3.21 3.21
  Annual energy consumption kWh   971 1,440 1,440 1,440         1,870 1,870 1,870
  COP     3.61 3.54 3.54 3.54         3.41 3.41 3.41
  Energy labeling Directive Cooling     A A A A         A A A
    Heating     A B B A         B B B
Heating capacity Nom. kW   7.5 10.8 10.8 10.8 (4)         13.5 13.5 13.5 (4)
Notes   (1) - EER/COP according to Eurovent 2012, for use outside EU only (1) - EER/COP according to Eurovent 2012, for use outside EU only (1) - EER/COP according to Eurovent 2012, for use outside EU only (1) - Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions)         (1) - EER/COP according to Eurovent 2012, for use outside EU only (1) - EER/COP according to Eurovent 2012, for use outside EU only (1) - Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions)
    (2) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load (2) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load (2) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load (2) - Energy label: scale from A (most efficient) to G (less efficient)         (2) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load (2) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load (2) - Energy label: scale from A (most efficient) to G (less efficient)
  (1) - EER/COP according to Eurovent 2012, for use outside EU only         (1) - EER/COP according to Eurovent 2012, for use outside EU only (1) - EER/COP according to Eurovent 2012, for use outside EU only (1) - EER/COP according to Eurovent 2012, for use outside EU only (1) - EER/COP according to Eurovent 2012, for use outside EU only       (1) - EER/COP according to Eurovent 2012, for use outside EU only (1) - EER/COP according to Eurovent 2012, for use outside EU only (1) - EER/COP according to Eurovent 2012, for use outside EU only (1) - EER/COP according to Eurovent 2012, for use outside EU only (1) - EER/COP according to Eurovent 2012, for use outside EU only (1) - EER/COP according to Eurovent 2012, for use outside EU only
          (3) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 5m; level difference: 0m             (3) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 5m; level difference: 0m
          (4) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m; level difference: 0m             (4) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m; level difference: 0m
          (5) - Annual energy consumption is according to Energy labeling directive 2002/31/EC             (5) - Annual energy consumption is according to Energy labeling directive 2002/31/EC
          (6) - SEER and SCOP are according to EN 14825             (6) - SEER and SCOP are according to EN 14825
          (7) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load             (7) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load