Specifications Table for FDXM-F3 / RZQSG-L3/9V1

FDXM35F3V1B / FDXM35F3V1B / RZQSG71L3V1B FDXM35F3V1B / FDXM35F3V1B / FDXM35F3V1B / RZQSG100L9V1B FDXM50F3V1B / FDXM50F3V1B / RZQSG100L9V1B FDXM35F3V1B / FDXM35F3V1B / FDXM35F3V1B / FDXM35F3V1B / RZQSG125L9V1B FDXM50F3V1B / FDXM50F3V1B / FDXM50F3V1B / RZQSG125L9V1B FDXM60F3V1B / FDXM60F3V1B / RZQSG125L9V1B
Space cooling Annual energy consumption kWh/a 467 693 652 875 875 875
  Capacity Pdesign kW 6.80 9.50 9.50 12.0 12.0 12.0
Space heating (Average climate) Capacity Pdesign kW 6.00 7.10 7.60 7.60 7.60 7.60
  Annual energy consumption kWh/a 2,211 2,616 2,800 2,800 2,800 2,800
Space cooling SEER   5.10 4.80 5.10 4.80 4.80 4.80
  Energy efficiency class   A B A B B B
Space heating (Average climate) SCOP/A   3.80 3.80 3.80 3.80 3.80 3.80
  Energy efficiency class   A A A A A A
Notes (1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m; level difference: 0m (1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m; level difference: 0m (1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m; level difference: 0m (1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m; level difference: 0m (1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m; level difference: 0m (1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m; level difference: 0m
  (2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m; level difference: 0m (2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m; level difference: 0m (2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m; level difference: 0m (2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m; level difference: 0m (2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m; level difference: 0m (2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m; level difference: 0m
  (3) - EER/COP according to Eurovent 2012, for use outside EU only (3) - EER/COP according to Eurovent 2012, for use outside EU only (3) - EER/COP according to Eurovent 2012, for use outside EU only (3) - EER/COP according to Eurovent 2012, for use outside EU only (3) - EER/COP according to Eurovent 2012, for use outside EU only (3) - EER/COP according to Eurovent 2012, for use outside EU only