Specifications Table for FDXM-F9 / 2MXM-A9

FDXM25F3V1B9 / FDXM25F3V1B9 / 2MXM40A2V1B9
Cooling capacity Nom. kW 4.00
Heating capacity Nom. kW 4.20
Nominal efficiency Annual energy consumption kWh 563
  COP   4.13
  EER   3.55
  Energy labeling Directive Cooling   A
    Heating   A
Space cooling Annual energy consumption kWh/a 223
  Energy efficiency class   A++
  Capacity Pdesign kW 4.00
  SEER   6.28
Space heating (Average climate) Annual energy consumption kWh/a 1,117
  Capacity Pdesign kW 3.20
  Energy efficiency class   A+
  Pdh Heating capacity at -10° kW 2.61
  SCOP/A   4.01
Notes (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
  (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
  (3) - See separate drawing for operation range
  (4) - See separate drawing for electrical data