FDXM25F3V1B9 / RXM25A5V1B9 |
FDXM35F3V1B9 / RXM35A5V1B9 |
FDXM50F3V1B9 / RXM50A5V1B9 |
Cooling capacity
|
Min.
|
kW
|
1.3
|
1.4
|
1.7
|
|
Nom.
|
kW
|
2.4
|
3.4
|
5
|
|
Max.
|
kW
|
3
|
3.8
|
5.3
|
Heating capacity
|
Min.
|
kW
|
1.3
|
1.4
|
1.7
|
|
Nom.
|
kW
|
3.2
|
4
|
5.8
|
|
Max.
|
kW
|
4.5
|
5
|
6
|
Nominal efficiency
|
EER
|
|
3.77
|
2.98
|
3.06
|
|
COP
|
|
4
|
3.48
|
3.1
|
|
Annual energy consumption
|
kWh
|
318
|
570
|
817
|
|
Energy labeling Directive
|
Cooling
|
|
A
|
C
|
B
|
|
|
Heating
|
|
A
|
B
|
D
|
Space cooling
|
Energy efficiency class
|
|
A+
|
A
|
A+
|
|
Capacity
|
Pdesign
|
kW
|
2.4
|
3.4
|
5
|
|
SEER
|
|
5.79
|
5.35
|
5.77
|
|
Annual energy consumption
|
kWh/a
|
145
|
222
|
303
|
Space heating (Average climate)
|
Energy efficiency class
|
|
A+
|
A
|
A
|
|
Capacity
|
Pdesign
|
kW
|
2.6
|
2.9
|
4
|
|
SCOP/A
|
|
4.29
|
3.95
|
3.93
|
|
Pdh Heating capacity at -10°
|
kW
|
2.15
|
2.32
|
3.54
|
|
Annual energy consumption
|
kWh/a
|
848
|
1028
|
1424
|
Notes
|
(1) - See separate drawing for operation range
|
(1) - See separate drawing for operation range
|
(1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
|
|
(2) - See separate drawing for electrical data
|
(2) - See separate drawing for electrical data
|
(2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
|
|
(3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
|
(3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
|
(3) - See separate drawing for operation range
|
|
(4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
|
(4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
|
(4) - See separate drawing for electrical data
|