Specifications Table for FDXM-F9 / RXM-N9

FDXM25F3V1B9 / RXM25N5V1B9 FDXM25F3V1B9 / RXM25N2V1B9 FDXM35F3V1B9 / RXM35N5V1B9 FDXM35F3V1B9 / RXM35N2V1B9 FDXM50F3V1B9 / RXM50N2V1B9 FDXM60F3V1B9 / RXM60N2V1B9
Cooling capacity Min. kW 1.30 1.30 1.40 1.40 1.70 1.70
  Max. kW 3.00 3.00 3.80 3.80 5.30 6.50
  Nom. kW 2.40 2.40 3.40 3.40 5.00 6.00
Space cooling SEER   5.68 5.68 5.26 5.26 5.77 5.56
  Annual energy consumption kWh/a 148 148 226 226 303 378
  Capacity Pdesign kW 2.40 2.40 3.40 3.40 5.00 6.00
  Energy efficiency class   A+ A+ A A A+ A
Space heating (Average climate) Capacity Pdesign kW 2.60 2.60 2.90 2.90 4.00 4.60
  SCOP/A   4.24 4.24 3.88 3.88 3.93 3.80
  Energy efficiency class   A+ A+ A A A A
  Annual energy consumption kWh/a 858 858 1,046 1,046 1,424 1,693
Nominal efficiency EER   3.77 3.77 2.98 2.98 3.06 2.93
  Annual energy consumption kWh 318 318 570 570 817 1,024
  COP   4.00 4.00 3.48 3.48 3.10 3.21
  Energy labeling Directive Cooling   A A C C B C
    Heating   A A B B D C
Heating capacity Nom. kW 3.20 3.20 4.00 4.00 5.80 7.00
  Min. kW 1.30 1.30 1.40 1.40 1.70 1.70
  Max. kW 4.50 4.50 5.00 5.00 6.00 7.10
Notes (1) - See separate drawing for electrical data (1) - See separate drawing for electrical data (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
  (2) - See separate drawing for operation range (2) - See separate drawing for operation range (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
  (3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (3) - See separate drawing for operation range (3) - See separate drawing for operation range (3) - See separate drawing for operation range (3) - See separate drawing for operation range
  (4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (4) - See separate drawing for electrical data (4) - See separate drawing for electrical data (4) - See separate drawing for electrical data (4) - See separate drawing for electrical data