Specifications Table for FDXS-F / RXL-K

FDXS25F2VEB / RXL25K3V1B FDXS35F2VEB / RXL35K2V1B FDXS50F2VEB / RXL50K2V1B
Cooling capacity Min. kW   1.4 1.7
  Max. kW   3.8 5.3
  Nom. kW 2.40 3.4 5.0
Space cooling SEER   5.08 5.27 5.44
  Annual energy consumption kWh/a 165 226 322
  Capacity Pdesign kW 2.40 3.40 5.00
  Energy efficiency class   B A A
Space heating (Average climate) Capacity Pdesign kW 2.60 2.90 3.50
  SCOP/A   4.09 3.83 3.41
  Energy efficiency class   A+ A A
  Annual energy consumption kWh/a 888 1,059 1,437
Nominal efficiency EER   3.48 3.21 3.03
  Annual energy consumption kWh 345 530 825
  COP   3.52 3.47 3.10
  Energy labeling Directive Cooling   A A B
    Heating   B B D
Heating capacity Nom. kW 3.20 4.10 5.80
  Min. kW   1.40 1.70
  Max. kW   5.00 6.00
Notes (1) - EER/COP according to Eurovent 2012, for use outside EU only (1) - EER/COP according to Eurovent 2012, for use outside EU only (1) - EER/COP according to Eurovent 2012, for use outside EU only
  (2) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load (2) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load (2) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load