Specifications Table for FFQ-B9V / RXS-K

FFQ25B9V1B / RXS25K2V1B FFQ25B9V1B / RXS25K3V1B FFQ35B9V1B / RXS35K2V1B FFQ50B9V1B / RXS50K2V1B
Cooling capacity Nom. kW 2.50 (3) 2.50 (3) 3.4 (3) 4.7 (3)
Space cooling SEER     4.36 4.53 5.14
  Annual energy consumption kWh/a   201 270 334
  Capacity Pdesign kW   2.50 3.50 4.90
  Energy efficiency class     C C A
Space heating (Average climate) Capacity Pdesign kW   2.80 2.90 4.50
  SCOP/A     3.75 3.49 3.41
  Energy efficiency class     A A A
  Annual energy consumption kWh/a   1,046 1,162 1,847
Piping connections Liquid OD mm     6.35 6.35
  Gas OD mm     9.5 12.7
  Drain OD mm     VP20 (External dia.26, Internal dia. 20) VP20 (External dia.26, Internal dia. 20)
Nominal efficiency EER   3.43 3.43 2.62 2.61
  Annual energy consumption kWh 365 365 650 900
  COP   3.48 3.48 2.81 2.81
  Energy labeling Directive Cooling   A A D D
    Heating   B B D D
Heating capacity Nom. kW 3.20 (4) 3.20 (4) 4.5 (4) 5.5 (4)
Notes (1) - Energy label: scale from A (most efficient) to G (less efficient) (1) - EER/COP according to Eurovent 2012, for use outside EU only (1) - EER/COP according to Eurovent 2012, for use outside EU only (1) - EER/COP according to Eurovent 2012, for use outside EU only
  (2) - Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) (2) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load (2) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load (2) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load
  (3) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB; equivalent piping length: 5m; level difference: 0m
  (4) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m; level difference: 0m
  (5) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load