| FTX20KV1B / RX20K2V1B | FTX20KV1B / RX20K5V1B | FTX25KV1B / RX25K2V1B | FTX25KV1B / RX25K5V1B | FTX35KV1B / RX35K2V1B | FTX35KV1B / RX35K5V1B | FTX50K2V1B / RX50K2V1B | FTX50KV1B / RX50KV1B | FTX60K2V1B / RX60K2V1B | FTX60KV1B / RX60KV1B | FTX71K2V1B / RX71K2V1B | ||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Cooling capacity | Min. | kW | 1.3 | 1.3 | 1.3 | 1.3 | 1.3 | 1.3 | 1.7 | 1.7 | 1.7 | 1.7 | 2.3 | |
| Max. | kW | 2.6 | 2.6 | 3.0 | 3.0 | 4.0 | 4.0 | 6.0 | 6.0 | 7.0 | 7.0 | 7.3 | ||
| Nom. | kW | 2.0 (2) | 2.0 (2) | 2.5 (2) | 2.5 (2) | 3.5 (2) | 3.5 (2) | 5.0 | 5.0 (2) | 6.0 | 6.0 (2) | 7.1 | ||
| Space cooling | SEER | 6.66 | 6.66 | 6.55 | 6.55 | 6.42 | 6.44 | 6.59 | 6.59 | 6.76 | 6.76 | 5.25 | ||
| Annual energy consumption | kWh/a | 105 | 106 | 134 | 134 | 180 | 191 | 266 | 266 | 311 | 311 | 473 | ||
| Capacity | Pdesign | kW | 2.00 | 2.00 | 2.50 | 2.50 | 3.50 | 3.50 | 5.00 | 5.00 | 6.00 | 6.00 | 7.10 | |
| Energy efficiency class | A++ | A++ | A++ | A++ | A++ | A++ | A++ | A++ | A++ | A++ | A | |||
| Space heating (Average climate) | Capacity | Pdesign | kW | 2.20 | 2.20 | 2.40 | 2.40 | 2.80 | 2.80 | 4.60 | 4.60 | 4.80 | 4.80 | 6.20 |
| SCOP/A | 4.65 | 4.65 | 4.61 | 4.61 | 4.64 | 4.64 | 4.10 | 4.10 | 4.10 | 4.10 | 3.81 | |||
| Energy efficiency class | A++ | A++ | A++ | A++ | A++ | A++ | A+ | A+ | A+ | A+ | A | |||
| Annual energy consumption | kWh/a | 662 | 663 | 729 | 729 | 845 | 845 | 1,570 | 1,570 | 1,640 | 1,640 | 2,277 | ||
| Piping connections | Liquid | OD | mm | 6.35 | 6.35 | 6.35 | 6.35 | 6.35 | 6.35 | 6.35 | 6.35 | |||
| Gas | OD | mm | 9.5 | 9.5 | 9.5 | 9.5 | 9.5 | 9.5 | 12.7 | 12.7 | ||||
| Drain | OD | mm | 18 | 18 | 18 | 18 | 18 | 18 | 16 | 16 | ||||
| Nominal efficiency | EER | 3.98 (1) | 3.98 (1) | 3.78 (1) | 3.78 (1) | 3.4 (1) | 3.4 (1) | 3.58 | 3.58 (1) | 3.65 | 3.65 (1) | 2.61 | ||
| Annual energy consumption | kWh | 251 | 251 | 331 | 331 | 510 | 510 | 698 | 698 | 822 | 822 | 1,360 | ||
| COP | 4.77 (1) | 4.77 (1) | 4.36 (1) | 4.36 (1) | 4.0 (1) | 4.0 (1) | 3.80 | 3.80 (1) | 3.63 | 3.63 (1) | 3.19 | |||
| Energy labeling Directive | Cooling | A | A | A | A | A | A | A | A | |||||
| Heating | A | A | A | A | A | A | A | A | ||||||
| Heating capacity | Nom. | kW | 2.5 (2) | 2.5 (2) | 3.0 (2) | 3.0 (2) | 4.0 (2) | 4.0 (2) | 6.0 | 6.0 (2) | 7.0 | 7.0 (2) | 8.2 | |
| Min. | kW | 1.3 | 1.3 | 1.3 | 1.3 | 1.3 | 1.3 | 1.7 | 1.7 | 1.7 | 1.7 | 2.3 | ||
| Max. | kW | 3.5 | 3.5 | 4.0 | 4.0 | 4.8 | 4.8 | 7.7 | 7.7 | 8.0 | 8.0 | 9.0 | ||
| Notes | (1) - EER/COP according to Eurovent 2012, for use outside EU only | (1) - EER/COP according to Eurovent 2012, for use outside EU only | (1) - EER/COP according to Eurovent 2012, for use outside EU only | (1) - EER/COP according to Eurovent 2012, for use outside EU only | (1) - EER/COP according to Eurovent 2012, for use outside EU only | (1) - EER/COP according to Eurovent 2012, for use outside EU only | (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | (1) - EER/COP according to Eurovent 2012, for use outside EU only | (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | (1) - EER/COP according to Eurovent 2012, for use outside EU only | (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | |||
| (2) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load | (2) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load | (2) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load | (2) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load | (2) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load | (2) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load | (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | (2) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load | (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | (2) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load | (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | ||||