FTXM20R2V1B / FTXM20R2V1B / 3MXM40N2V1B7 |
FTXM20R5V1B / FTXM20R5V1B / 3MXM40N2V1B7 |
FTXM25R2V1B / FTXM25R2V1B / 3MXM52N2V1B7 |
FTXM25R5V1B / FTXM25R5V1B / 3MXM52N2V1B7 |
Cooling capacity
|
Nom.
|
kW
|
4.00
|
4.00
|
5.00
|
5.0, 5.00
|
Space cooling
|
SEER
|
|
8.52
|
8.52
|
8.59
|
8.59
|
|
Annual energy consumption
|
kWh/a
|
165
|
165
|
204
|
204
|
|
Capacity
|
Pdesign
|
kW
|
4.00
|
4.00
|
5.00
|
5.00
|
|
Energy efficiency class
|
|
A+++
|
A+++
|
A+++
|
A+++
|
Space heating (Average climate)
|
Capacity
|
Pdesign
|
kW
|
4.80
|
4.80
|
4.80
|
4.80
|
|
SCOP/A
|
|
4.24
|
4.24
|
4.38
|
4.38
|
|
Energy efficiency class
|
|
A+
|
A+
|
A+
|
A+
|
|
Pdh Heating capacity at -10°
|
kW
|
3.60
|
3.60
|
3.90
|
3.90
|
|
Annual energy consumption
|
kWh/a
|
1,582
|
1,582
|
1,533
|
1,533
|
Nominal efficiency
|
Annual energy consumption
|
kWh
|
420
|
420
|
515
|
515
|
|
EER
|
|
4.76
|
4.76
|
4.85
|
4.85
|
|
COP
|
|
4.73
|
4.73
|
4.45
|
4.45
|
|
Energy labeling Directive
|
Cooling
|
|
A
|
A
|
A
|
A
|
|
|
Heating
|
|
A
|
A
|
A
|
A
|
Heating capacity
|
Nom.
|
kW
|
4.60
|
4.60
|
6.80
|
6.80
|
Notes
|
(1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
|
(1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
|
(1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
|
(1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
|
|
(2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
|
(2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
|
(2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
|
(2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
|
|
(3) - See separate drawing for operation range
|
(3) - See separate drawing for operation range
|
(3) - See separate drawing for operation range
|
(3) - See separate drawing for operation range
|
|
(4) - See separate drawing for electrical data
|
(4) - See separate drawing for electrical data
|
(4) - See separate drawing for electrical data
|
(4) - See separate drawing for electrical data
|