Specifications Table for FTXM-R / 3MXM-N7

FTXM20R2V1B / FTXM20R2V1B / 3MXM40N2V1B7 FTXM20R5V1B / FTXM20R5V1B / 3MXM40N2V1B7 FTXM25R2V1B / FTXM25R2V1B / 3MXM52N2V1B7 FTXM25R5V1B / FTXM25R5V1B / 3MXM52N2V1B7
Cooling capacity Nom. kW 4.00 4.00 5.00 5.0, 5.00
Space cooling SEER   8.52 8.52 8.59 8.59
  Annual energy consumption kWh/a 165 165 204 204
  Capacity Pdesign kW 4.00 4.00 5.00 5.00
  Energy efficiency class   A+++ A+++ A+++ A+++
Space heating (Average climate) Capacity Pdesign kW 4.80 4.80 4.80 4.80
  SCOP/A   4.24 4.24 4.38 4.38
  Energy efficiency class   A+ A+ A+ A+
  Pdh Heating capacity at -10° kW 3.60 3.60 3.90 3.90
  Annual energy consumption kWh/a 1,582 1,582 1,533 1,533
Nominal efficiency Annual energy consumption kWh 420 420 515 515
  EER   4.76 4.76 4.85 4.85
  COP   4.73 4.73 4.45 4.45
  Energy labeling Directive Cooling   A A A A
    Heating   A A A A
Heating capacity Nom. kW 4.60 4.60 6.80 6.80
Notes (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
  (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
  (3) - See separate drawing for operation range (3) - See separate drawing for operation range (3) - See separate drawing for operation range (3) - See separate drawing for operation range
  (4) - See separate drawing for electrical data (4) - See separate drawing for electrical data (4) - See separate drawing for electrical data (4) - See separate drawing for electrical data