| FTXS60FV1B / RXS60F2V1B | FTXS71FV1B / RXS71FV1B | ||||
|---|---|---|---|---|---|
| Cooling capacity | Min. | kW | 1.7 | 2.3 | |
| Max. | kW | 6.7 | 8.5 | ||
| Nom. | kW | 6.0 (1) | 7.1 (1) | ||
| Piping connections | Liquid | OD | mm | 6.35 | 6.35 |
| Gas | OD | mm | 12.7 | 15.9 | |
| Drain | OD | mm | 18.0 | 18.0 | |
| Nominal efficiency | EER | 3.02 | 3.02 | ||
| Annual energy consumption | kWh | 995 | 1,175 | ||
| COP | 3.43 | 3.22 | |||
| Energy labeling Directive | Cooling | B | B | ||
| Heating | B | C | |||
| Heating capacity | Nom. | kW | 7.0 (2) | 8.2 (2) | |
| Min. | kW | 1.7 | 2.3 | ||
| Max. | kW | 8.0 | 10.2 | ||
| Notes | (1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 7.5m | (1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 7.5m | |||
| (2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m | (2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m | ||||
| (3) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load | (3) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load | ||||