| FVA100AMVEB / RZQG71L9V1B | FVA71AMVEB / RZQG71L9V1B | FVA100AMVEB / RZQG100L9V1B | FVA140AMVEB / RZQG100L9V1B | FVA125AMVEB / RZQG125L9V1B | FVA140AMVEB / RZQG125L9V1B | FVA140AMVEB / RZQG140L9V1B | ||||
|---|---|---|---|---|---|---|---|---|---|---|
| Cooling capacity | Nom. | kW | 6.80 | 6.80 | 9.50 | 9.50 | 12.00 | 12.00 | 13.40 | |
| Space cooling | SEER | 6.23 | 6.23 | 5.61 | 5.61 | 5.61 | 5.61 | 5.89 | ||
| ηs,c | % | 232.61 | ||||||||
| Annual energy consumption | kWh/a | 383 | 383 | 593 | 593 | 749 | 749 | 1,365 | ||
| Capacity | Pdesign | kW | 6.80 | 6.80 | 9.50 | 9.50 | 12.00 | 12.00 | 13.40 | |
| Energy efficiency class | A++ | A++ | A+ | A+ | A+ | A+ | ||||
| Space heating (Average climate) | Capacity | Pdesign | kW | 6.33 | 6.33 | 11.30 | 11.30 | 11.30 | 11.30 | 11.47 |
| SCOP/A | 4.05 | 4.05 | 4.20 | 4.20 | 3.87 | 3.87 | 3.88 | |||
| Energy efficiency class | A+ | A+ | A+ | A+ | A | A | ||||
| Annual energy consumption | kWh/a | 2,189 | 2,189 | 3,767 | 3,767 | 4,088 | 4,088 | 4,132 | ||
| ηs,h | % | 152.39 | ||||||||
| Nominal efficiency | EER | 3.37 | 3.37 | 3.81 | 3.81 | 3.21 | 3.21 | 2.79 | ||
| Annual energy consumption | kWh | 1,009 | 1,247 | 1,869 | ||||||
| COP | 3.64 | 4.14 | 3.70 | 3.61 | ||||||
| Energy labeling Directive | Cooling | A | A | A | ||||||
| Heating | A | A | A | |||||||
| Heating capacity | Nom. | kW | 7.50 | 10.80 | 13.50 | 15.50 | ||||
| Notes | (1) - See separate drawing for operation range | (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | (1) - See separate drawing for operation range | (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | (1) - See separate drawing for operation range | (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | |||
| (2) - See separate drawing for electrical data | (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | (2) - See separate drawing for electrical data | (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | (2) - See separate drawing for electrical data | (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | ||||
| (3) - See separate drawing for operation range | (3) - See separate drawing for operation range | (3) - See separate drawing for operation range | (3) - See separate drawing for operation range | |||||||
| (4) - See separate drawing for electrical data | (4) - See separate drawing for electrical data | (4) - See separate drawing for electrical data | (4) - See separate drawing for electrical data | |||||||