Specifications Table for FVXG-K / RXLG-K

FVXG25K2V1B / RXLG25K2V1B FVXG25K2V1B / RXLG25K3V1B FVXG35K2V1B / RXLG35K2V1B FVXG35K2V1B / RXLG35K3V1B FVXG50K2V1B / RXLG50K2V1B FVXG50K2V1B / RXLG50K3V1B
Cooling capacity Min. kW 1.3 1.3 1.4 1.4 1.7 1.7
  Max. kW 3.0 3.0 3.8 3.8 5.6 5.6
  Nom. kW 2.5 (3) 2.5 (2) 3.5 (3) 3.5 (2) 5.0 (2) 5.0 (2)
Space cooling SEER     6.46   6.33   5.31
  Annual energy consumption kWh/a   135   194   330
  Capacity Pdesign kW   2.50   3.50   5.00
  Energy efficiency class     A++   A++   A
Space heating (Average climate) Capacity Pdesign kW   2.80   3.10   4.60
  SCOP/A     4.47   3.87   4.08
  Energy efficiency class     A+   A   A+
  Annual energy consumption kWh/a   877   1,122   1,577
Piping connections Liquid OD mm 6.35 6.35 6.35 6.35 6.35 6.35
  Gas OD mm 9.5 9.5 9.5 9.5 12.7 12.7
  Drain OD mm   18.0   18.0 18.0 18.0
Nominal efficiency EER   4.55 4.55 3.68 3.68 3.29 (1) 3.29 (1)
  Annual energy consumption kWh 275 275 476 475 760 760
  COP   4.36 4.36 3.72 3.72 3.67 (1) 3.67 (1)
  Energy labeling Directive Cooling   A A A A A A
    Heating   A A A A A A
Heating capacity Nom. kW 3.4 (4) 3.4 (3) 4.5 (4) 4.5 (3) 5.8 (3) 5.8 (3)
  Min. kW 1.3 1.3 1.4 1.4 1.7 1.7
  Max. kW 4.5 4.5 5.0 5.0 8.1 8.1
Notes (1) - Energy label: scale from A (most efficient) to G (less efficient) (1) - EER/COP according to Eurovent 2012, for use outside EU only (1) - Energy label: scale from A (most efficient) to G (less efficient) (1) - EER/COP according to Eurovent 2012, for use outside EU only (1) - EER/COP according to Eurovent 2012, for use outside EU only (1) - EER/COP according to Eurovent 2012, for use outside EU only
  (2) - Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) (2) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m (horizontal) (2) - Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) (2) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m (horizontal) (2) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m (2) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m
  (3) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m (horizontal) (3) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m (horizontal) (3) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m (horizontal) (3) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m (horizontal) (3) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m (3) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m
  (4) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m (horizontal) (4) - 220V (4) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m (horizontal) (4) - 220V (4) - 220V (4) - 220V
  (5) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load (5) - 230V (5) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load (5) - 230V (5) - 230V (5) - 230V
    (6) - 240V   (6) - 240V (6) - 240V (6) - 240V
    (7) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load   (7) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load (7) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load (7) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load