Specifications Table for FXMA-A

FXMA50A5VEB FXMA63A5VEB FXMA80A5VEB FXMA100A5VEB FXMA125A5VEB FXMA200AXVMB FXMA250AXVMB
Cooling capacity Total capacity At high fan speed kW 5.6 7.1 9.0 11.2 14.0 22.4 28.0
Heating capacity Total capacity At high fan speed kW 6.3 8.0 10.0 12.5 16.0 25.0 31.5
Power input - 50Hz Cooling At high fan speed kW 0.125 0.140 0.198 0.191 0.254 0.54 0.65
  Heating At high fan speed kW 0.125 0.140 0.198 0.191 0.254 0.54 0.65
Dimensions Unit Height mm 300 300 300 300 300 470 470
    Width mm 1000 1000 1000 1400 1400 1490 1490
    Depth mm 700 700 700 700 700 1100 1100
Weight Unit kg 35 35 35 46 46 105 115
Casing Colour   Unpainted Unpainted Unpainted Unpainted Unpainted Unpainted Unpainted
  Material   Galvanised steel plate Galvanised steel plate Galvanised steel plate Galvanised steel plate Galvanised steel plate Galvanised steel plate Galvanised steel plate
Required ceiling void > mm 350 350 350 350 350
Fan Air flow rate - 50Hz Cooling At high fan speed m³/min 18.0 19.5 25.0 32.0 36.0 62 74
      At low fan speed m³/min 15.0 16.0 20.0 23.0 26.0 41 52
  External static pressure - 50Hz High Pa 200 200 200 200 200 250 250
    Low Pa           50 50
  External static pressure - 60Hz High Pa 200 200 200 200 200 250 250
    Low Pa           50 50
Refrigerant Type   R-32 R-32 R-32 R-32 R-32 R-32 R-32
  GWP   675 675 675 675 675 675 675
Sound power level Cooling At high fan speed dBA 61.0 64.0 67.0 65.0 70.0 75.0 76.0
Sound pressure level Cooling At high fan speed dBA 41.0 42.0 43.0 43.0 44.0 48.0 48.0
    At medium fan speed dBA 39.0 40.0 41.0 41.0 42.0 46.5 46.5
    At low fan speed dBA 37.0 38.0 39.0 39.0 40.0 45.0 45.0
  Heating At high fan speed dBA 41.0 42.0 43.0 43.0 44.0 48.0 48.0
    At medium fan speed dBA 39.0 40.0 41.0 41.0 42.0 46.5 46.5
    At low fan speed dBA 37.0 38.0 39.0 39.0 40.0 45.0 45.0
Piping connections Liquid Type   Flare connection Flare connection Flare connection Flare connection Flare connection Flare connection Flare connection
    OD mm 6.35 6.35 6.35 9.52 9.52 9.5 9.5
  Gas Type   Flare connection Flare connection Flare connection Flare connection Flare connection Flange Flange
    OD mm 12.7 12.7 12.7 15.9 15.9 19.1 19.1
  Drain   VP25 (I.D. 25/O.D. 32) VP25 (I.D. 25/O.D. 32) VP25 (I.D. 25/O.D. 32) VP25 (I.D. 25/O.D. 32) VP25 (I.D. 25/O.D. 32) BSP1 BSP1
Air filter Type   Resin net Resin net Resin net Resin net Resin net
Standard Accessories General safety precautions           1 1
  Wire clamp material           1 1
  Spring washer           2 2
  Hexagon head screw           2 2
  Plain washer           8 8
  Hexagon head screw with washer           49 49
  Gas connection pipe           1 1
  Installation and operation manual 1 1 1 1 1 1 1
Power supply Name   VE VE VE VE VE VM VM
  Phase   1~ 1~ 1~ 1~ 1~ 1~ 1~
  Frequency Hz 50/60 50/60 50/60 50/60 50/60 50/60 50/60
  Voltage V 220-240/220 220-240/220 220-240/220 220-240/220 220-240/220 220-240/220-230 220-240/220-230
Current - 50Hz Maximum fuse amps (MFA) A 6 6 6 6 6 6 6
Standard Accessories Washer for hanger bracket 8 8 8 8 8
  Drain hose 1 1 1 1 1
  Insulation for fitting 2 2 2 2 2
  Metal clamp for drain hose 1 1 1 1 1
  Screws 16 16 16 16 16
  Sealing pad 3 3 3 3 3
Notes (1) - Values are valid for the factory setting. (1) - Values are valid for the factory setting. (1) - Values are valid for the factory setting. (1) - Values are valid for the factory setting. (1) - Values are valid for the factory setting.
  (2) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 5m; level difference: 0m (2) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 5m; level difference: 0m (2) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 5m; level difference: 0m (2) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 5m; level difference: 0m (2) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 5m; level difference: 0m
  (3) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m; level difference: 0m (3) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m; level difference: 0m (3) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m; level difference: 0m (3) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m; level difference: 0m (3) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m; level difference: 0m
  (4) - Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. (4) - Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. (4) - Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. (4) - Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. (4) - Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.
  (5) - External static pressure is changeable to set by the remote control (from standard to high, see installation manual) (5) - External static pressure is changeable to set by the remote control (from standard to high, see installation manual) (5) - External static pressure is changeable to set by the remote control (from standard to high, see installation manual) (5) - External static pressure is changeable to set by the remote control (from standard to high, see installation manual) (5) - External static pressure is changeable to set by the remote control (from standard to high, see installation manual)
  (6) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits. (6) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits. (6) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits. (6) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits. (6) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits.
  (7) - Maximum allowable voltage range variation between phases is 2%. (7) - Maximum allowable voltage range variation between phases is 2%. (7) - Maximum allowable voltage range variation between phases is 2%. (7) - Maximum allowable voltage range variation between phases is 2%. (7) - Maximum allowable voltage range variation between phases is 2%.
  (8) - MCA/MFA: MCA = 1.1 x FLA (8) - MCA/MFA: MCA = 1.1 x FLA (8) - MCA/MFA: MCA = 1.1 x FLA (8) - MCA/MFA: MCA = 1.1 x FLA (8) - MCA/MFA: MCA = 1.1 x FLA
  (9) - Instead of a fuse, use a circuit breaker (9) - Instead of a fuse, use a circuit breaker (9) - Instead of a fuse, use a circuit breaker (9) - Instead of a fuse, use a circuit breaker (9) - Instead of a fuse, use a circuit breaker
  (10) - Select wire size based on the value of MCA (10) - Select wire size based on the value of MCA (10) - Select wire size based on the value of MCA (10) - Select wire size based on the value of MCA (10) - Select wire size based on the value of MCA
  (11) - Contains fluorinated greenhouse gases (11) - Contains fluorinated greenhouse gases (11) - Contains fluorinated greenhouse gases (11) - Contains fluorinated greenhouse gases (11) - Contains fluorinated greenhouse gases