| LRLEQ3BY1 | LRLEQ4BY1 | |||||
|---|---|---|---|---|---|---|
| Refrigerating capacity | Low temperature | Nom. | kW | 2.78 (1) | 3.62 (1) | |
| Power input | Low temperature | Nom. | kW | 2.60 (1) | 3.41 (1) | |
| COP | Low temperature | Nom. | 1.07 (1) | 1.06 (1) | ||
| Annual electricity consumption Q | R-410A | Te -35°C | kWh/a | 11920 | 16048 | |
| Seasonal energy performance ratio SEPR | R-410A | Te -35°C | 1.74 | 1.68 | ||
| Parameters at full load and ambient temp. 32°C (Point A) | R-410A | Te -35°C | Rated cooling capacity (PA) | kW | 2.78 | 3.62 |
| Rated power input (DA) | kW | 2.60 | 3.41 | |||
| Rated COP (COPA) | 1.07 | 1.06 | ||||
| Parameters at full load and ambient temp. 43°C | R-410A | Te -35°C | Declared COP (COP3) | 0.59 | 0.66 | |
| Fan motor | Drive | Direct drive | Direct drive | |||
| Fan | Quantity | 2 | 2 | |||
| Type | Propeller | Propeller | ||||
| Air flow rate | Cooling | Nom. | m³/min | 106 | 106 | |
| Fan motor | Output | W | 70 | 70 | ||
| Dimensions | Unit | Height | mm | 1345 | 1345 | |
| Width | mm | 900 | 900 | |||
| Depth | mm | 320 | 320 | |||
| Weight | Unit | kg | 130 | 130 | ||
| Refrigerant | Type | R-410A | R-410A | |||
| Casing | Colour | Daikin White | Daikin White | |||
| Refrigerant | GWP | 2,087.5 | 2,087.5 | |||
| Heat exchanger | Type | Cross fin coil | Cross fin coil | |||
| Refrigerant | Charge | kg | 6.90 | 6.90 | ||
| Charge | tCO2Eq | 14.4 | 14.4 | |||
| Standard Accessories | Installation manual | 1 | 1 | |||
| General safety precautions | 1 | 1 | ||||
| Power supply | Phase | 3N~ | 3N~ | |||
| Frequency | Hz | 50 | 50 | |||
| Voltage | V | 380-415 | 380-415 | |||
| Notes | (1) - Cooling: evaporating temp. -35°C; outdoor temp. 32°C; suction SH10°C | (1) - Cooling: evaporating temp. -35°C; outdoor temp. 32°C; suction SH10°C | ||||
| (2) - Sound pressure data: measured at 1m in front of unit, at 1.5m height | (2) - Sound pressure data: measured at 1m in front of unit, at 1.5m height | |||||